16-Throughput Nucleic Acid Extraction System - MultiEX 016

Out of stock
Regular price $4,070.00
Regular price Sale price $4,070.00
Sale Contact Us
Product Information Product code : MultiEX 016

MultiEX 016 is an automated nucleic acid extraction and purification system which can process up to 16 samples per run. Utilizing Magnetic Bead Separation technology, the Nucleic Acid Extractor has the capability of extracting and purifying nucleic acids from a variety of biological samples, such as whole blood, viruses, tissues, plants, animals, fungi, bacteria, cultured cells, swabs, feces, blood cards, etc.

MultiEX 016 features lightweight and compact design, user-friendly touchscreen interface and excellent mixing capability. It can be powered by a 24V external battery, enabling mobile on-site nucleic acid extraction. It is equipped with UV disinfection system to eliminate cross-contamination between runs.

How it works

Prep & Transfer

Prepare samples by adding lysis buffer and bead solution as appropriate to sample and homogenize it into the 96-well plate.

Start Extraction

Using the touchscreen interface, program the incubation temperature, duration, and agitation speed. The extractor will automatically with extraction, including magnetic bead capture, washing, and elution.

Collect Nucleic Acid

Once extraction is complete, the system will dispense purified nucleic acid into a clean, new 96-well plate, ready for downstream analysis.

16-Throughput Nucleic Acid Extraction System - MultiEX 016

We’re Serving Laboratory Market Worldwide

At 4E's, we ensure quality by implementing rigorous testing and inspection protocols on our products, which allows us to deliver reliable laboratory equipment to our customers. Our knowledgeable and responsive support team provides excellent customer assistance, ensuring that our customers receive the best possible experience when working with us.

10,000+

Customers

3,000+

Answered calls

5,000+

Emails answered

Specification

Model MultiEX 016
Processing volume 50-1000ul
Throughput 1-16 samples
Plate quantity 1
Plate type 96-Deep Well Plate (conical/round bottom)
Processing time 20min-40min/run (depending on reagent types and volumes)
Reagent type Magnetic bead-based reagent kits (open system)
Program management Create&Edit and Delete options available
Heating temperature Room temperature~125℃
Temperature accuracy 1.5℃
Magnetic beads recovery rate 96%
Inter-well purification variance CV<5%
Noise <55db
Mixing intensities Adjustable: 8 Levels
Data storage capacity >500 programs
Dimension 210mm*250mm*315mm
Display 7-inch color touchscreen
Lighting YES
UV sterilization YES
Power supply 200-240V,100-120V 50/60Hz(can be powered by a 24V,5A battery)
Weight 9KG
Extension ports 2 USB ports
High-throughput Processing
Magnetic Bead Technology
User-friendly Interface

High-throughput Processing

MultiEX 016 can process up to 16 samples in a single run, allowing for high-throughput extraction of nucleic acid.

Magnetic Bead Technology

The use of magnetic beads allows for efficient and selective capture of nucleic acid, resulting in high yields of pure DNA or RNA.

User-friendly Interface

The touchscreen interface is easy to navigate and allows for quick and simple programming of extraction parameters.

High-throughput Processing Magnetic Bead Technology User-friendly Interface
High-throughput Processing High-throughput Processing
Magnetic Bead Technology Magnetic Bead Technology
User-friendly Interface User-friendly Interface

High-throughput Processing

MultiEX 016 can process up to 16 samples in a single run, allowing for high-throughput extraction of nucleic acid.

Magnetic Bead Technology

The use of magnetic beads allows for efficient and selective capture of nucleic acid, resulting in high yields of pure DNA or RNA.

User-friendly Interface

The touchscreen interface is easy to navigate and allows for quick and simple programming of extraction parameters.

High-throughput Processing Magnetic Bead Technology User-friendly Interface

Advanced heating control

The system includes multiple heating modules with individual temperature control to ensure optimal temperature accuracy during lysis and elution steps. This allows for precise temperature control and eliminates the risk of overheating or underheating during the extraction process, which can lead to degradation of nucleic acid and poor results.

Minimal Hands-On Time

The MultiEX 016 is fully automated, reducing the need for manual intervention and minimizing the risk of contamination. This allows for reliable and reproducible results, even when processing large numbers of samples. The system also has an auto-check function that ensures the correct positioning of the 96-well plate and magnetic rods, further reducing the risk of errors.

Compact Design

The MultiEX 016 has a small footprint, making it ideal for use in laboratories with limited bench space. The system is also easy to set up and use, requiring minimal maintenance and no special infrastructure or installation. Its compact design and ease of use make it an attractive option for labs with limited resources or space.

Frequently Asked Questions

Everything you need to know about product and billing. Can’t find the answer you are looking for? Please write your question to us at info@4Es-USA.com

Is there warranty of this device?